Learn to identify when foundation cracks are normal or when foundation cracking is a sign of foundation problems. At one time there were problems with corrosion of the cables, especially in. May 14, 2020 a post tension slab is a slab of concrete that has been prestressed using a specific method to increase the strength of the concrete. Cracks are categorized as occurring either in plastic concrete or hardened concrete. Each type of concrete foundation, wall, basement slab, floor slab, or slab on grade crack is discussed and described with photographs below. Construction issues in seneca structural engineering. And from what ive seen the cost of conventional vs post tension is about a wash. There are several post tension slab problems which can be avoided. Avoiding post tension errors which result in cracking.
The compressive stresses resist the anticipated tension stresses induced by the soil movements, enhancing the performance over a nonprestressed foundation. Pre tensioned beams may present cracking problems at the time of stress relief, especially in beams that are less than one day old. However, for the first 4 months no cracks at all were visible. Posttensioned concrete is a unique structural system that is widely used to construct many types of structures such as bridges, parking structures, buildings and tanks. Significant overbalancing of the weight of the concrete with posttensioning can actually lift and crack the slab.
Types of cracks in fresh and hardened concrete causes and. Post tensioning is a technique for reinforcing concrete. Post tensioning, which is a form of prestressing, has several advantages over standard reinforcing steel rebars. The cause of cracking in posttensioned concrete box girder. Post tensioned slab design is widely used in the world, with the main benefits over conventionally reinforced concrete being its ability to span greater distances without resorting to thick slabs and beams and the consequent loss of head height, and reduce deflection and cracking. In most or even all cases, we eventually repair and re. Hi im fred marshal with advanced foundation repair. Knowing the ways and the extent to which problems can occur helps us. Preventing cracks on posttensioned concrete slabs pro builder. To prevent this problem, the stressing operation should start as soon as the. Posttensioned prestressed concrete as a building material, concrete is strong in compression, but weak in tension. Usually a sign in the garage or stamp in the slab will indicate if your home has a post tension slab. Posttensioning, which is a form of prestressing, has several advantages over standard reinforcing steel rebars. All concrete will shrink during the curing process which lasts up to a.
It allows us to build slabs on expansive or soft soils. We know how to collaborate with public and private sector clients. Before a posttension slab is poured, highstrength steel strands or cables, called tendons, are laid in a tight grid. It reduces or eliminates shrinkage cracking therefore no joints, or fewer joints, are needed.
The major benefit of posttensioned concrete construction over the old standard reinforced concrete is pt concrete slabs do not need the same amount of pavement joints to control cracking. Post tensioning tendons, which are prestressing steel cables inside plastic ducts or sleeves, are positioned in the forms before the concrete is placed. Moisture infiltration can occur from numerous sources including initial construction, ground water, roof leakage, and poor quality grout pockets. Posttensioned concrete courts provide many advantages, the design of the system will greatly decrease the chances for cracking, settling and ponding. Posttensioning will reduce cracking and keep any cracks that might.
The best way to ensure this doesnt happen is to educate your construction teams on the best practices for designing and constructing post tensioned slabs. Post tension slabs answers to questions buyers ask. Flexural cracking due to sustained posttensioning forces is believed to be more severe than cracking due to transient loading. There are several basic advantages for a post tension slab. The cause of cracking in posttensioned concrete box girder bridges and retrofit procedures walter podolny, jr. Post tensioned foundation information for the homeowner.
Avoiding posttension errors which result in cracking. Slabonground post tensioned slabsonground provide a costefficient, highperformance solution for problems associated with groundsupported residential foundations on shrinkswell soils. Shrinkage crack considerations for posttensioned foundations june 1, 2015 shrinkage cracks in concrete slabonground foundations are a significant public relations problem to home builders. Expansion joints in posttensioned parking structures. Some of the cracks are more than 30 feet long, and i can feel a slight difference in the rise on each side you can even. Reinforcement helps extend the life of concrete, overcoming cracking that is inherent in the material and preventing its failure. Post tension slab services post tension concrete, cable. Post tensioning tendons, which are highstrength steel cables inside plastic sheathing, are positioned in the forms before the concrete is placed. The foundation in question was a post tension cable reinforced foundation as opposed to a foundation which is reinforced with steel rebar see the typical photograph in this article. When are foundation cracks normal or signs of foundation. Posttensioning is a method of reinforcing strengthening concrete or other materials with highstrength steel strands rebars, typically referred to as tendons. Advantages of using posttensioning for your next slabonground project. This means the foundation is reinforced by cables laid in a grid arrangement and tensioned after the concrete cures sufficiently with the intent to create.
Top 10 biggest mistakes made in posttensioned concrete design. But since a post tensioned slab does not have excess rebar to minimize and distribute crack ing, restraint cracks will be large and very noticeable. Structure magazine posttensioned concrete construction. Miyagi construction concrete restoration,posttension. Jun 22, 2011 post tension nightmare post tension foundation problems in arizona concrete repairman duration. Posttensioning methods for reinforcing concrete the. Typically maximum fiber stress in tension controls design. Any post tension slab inspectors out there i am building a new home in longview, texas, and they poured our post tension slab 7 days ago. Shrinkage crack considerations for posttensioned foundations. It allows slabs and other structural members to be thinner. The cause of cracking in post tensioned concrete box girder bridges and retrofit procedures walter podolny, jr. This tension makes the concrete slab and foundation much stronger than concrete without reinforcement and helps reduce cracking.
Post tension slabs superior foundations services jackson. By the third day, i noticed a crack in the back patio, and by the fourth, there were sprawling cracks throughout the entire foundation. Less concrete and steel are needed for the same structural capacity and the slab stiffness is increased so that the slab is better able to resist bending caused by differential soil movements. Balanced load in posttension concrete home articles precompression vs. Several methods exist for prestressing concrete, with post tensioning being a very common one.
This technique adds flexural and shear reinforcement to the element in an ex terior concrete shell that is cast. On the premise that those who ignore history will be condemned to relive it, this paper attempts to document those types of problems that lead. Mar 09, 2020 with concrete, weather is an important factor, as wet or dry conditions can significantly change the timing of when you stress the tendons. Cracks, cracks, cracks what is a reasonable level of cracking. Post tension services of texas ptst is a full service post tensioning company based in dallas. As we all know, concrete tends to crack over time it helps spread the load weight of the home over the entire slab area verses just on the footing area. One of the most common forms of balcony problems in our area coastal south florida is corrosionrelated cracking and spalling of balcony slab edges. Restraint cracks are often large and noticeable since a posttensioned slab does not have the excess rebar to minimize and distribute cracking. Balanced load in posttension concrete my post tension elevator speech is pretty well rehearsed at this point. Posttensioning is a method of reinforcing strengthening concrete or other.
Post tensioning in concrete slab benefits and advantages. Insufficient concrete cover over the cables, lack of waterproofing at anchorages and errors made during initial construction can lead to widespread corrosion problems within posttensioning systems. Looks like precast on a poured concrete wall to me, not slab on grade and no real indication that the slab is post tensioned, if it was. We drape steel cables tendons in the concrete forms, and then place the concrete. Jul, 2012 learn to identify when foundation cracks are normal or when foundation cracking is a sign of foundation problems. Concrete can support a lot of weight in compression, but is weak in tension. Post tensioned concrete construction is a little different than standard reinforced concrete construction. In order to ensure that the post tension slab used will have the best chance of avoiding. There are several construction issues with post tensioned concrete that are found consistently among engineers and contractors. Posttensioning tendons, which are prestressing steel cables inside plastic ducts or sleeves, are positioned in the forms before the concrete is placed.
Corrosion is a common problem for unbonded posttensioned cables exposed to moisture and aggressive environments. The slab is five inches thick with tendons spaced at 30 iches o. The slab has numerous surface cracks which resemble typical shrinkage cracking. When are foundation cracks normal or signs of foundation problems. Afterwards, once the concrete has gained strength but before the service loads are applied, the cables are pulled tight, or tensioned. Founded in 1904 and headquartered in farmington hills, michigan, usa, the american concrete institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensusbased standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design. A reinforced concrete pavement will require joints to control cracking as close as 12 feet in all directions, which result in joints being located within the. Effective inspection and monitoring of posttensioned structures. When the foundationconcrete has sufficiently hardenedcured, the plasticsheathing is stretchedelongated. Concrete cracks due to inclusions of shale and iron sulfide mineral pyrrhotite cracking. I had a call this morning from a prospective client who was concerned about cracks in the concrete foundation of the home they. Shrinkage crack considerations for post tensioned foundations june 1, 2015 shrinkage cracks in concrete slabonground foundations are a significant public relations problem to home builders. Posttension services of texas ptst is a full service posttensioning company based in dallas.
Post tensioned tennis court cracking concrete engineering. Post tensioned slabs are a great tool to help reduce joints and control cracks. You need to pay particular attention to the storage of materials and operational equipment during the construction phase, as these may generate loads that exceed those that the structure was designed to withstand. Our future vision pti envisions a future in which post tensioning is the first choice for reinforcing all structures. Problems in largescale prestressed concrete construction ben c.
Home builders can avoid cracks in a posttensioned concrete slabongrade. The cracks began to appear after 4 months and have increased in number. Lots of cracks in new post tension slab inspectionnews. Several methods exist for prestressing concrete, with posttensioning being a very common one. Rebar reinforcement in this case is technically allowed by code but in our experience, a properly designed post tensioned concrete slab will minimize cracking due to shrinkage. There are several construction issues with posttensioned concrete that are found consistently among engineers and contractors. Posttensioning pt delivers roughly four times the tensile strength compared to conventional reinforcement and significantly reduces or eliminates concrete cracking, thus enabling thinner slab construction reducing the environmental impacts, saving material and labor costs, and shortening construction schedules. Understanding the causes of some of these problems should help contractors build better post tensioned structures.
Through our proven preconstruction services approach, project construction management systems, and designbuild techniques, our teams is ideally suited to handle the complex projects of the institutional sector. The foundation in question was a posttension cable reinforced foundation as opposed to a foundation which is reinforced with steel rebar see the typical photograph in this article. Stretching or elongating the posttensioned cables applies significant force to the concrete system, lifting the slab into a compressed state, which reduces the negative effects from tensile forces cracking. Stretching or elongating the post tensioned cables applies significant force to the concrete system, lifting the slab into a compressed state, which reduces the negative effects from tensile forces cracking. On the other hand posttension slabs allow for the soil compaction due to decay and are strong enough to avoid the associated cracking. Our future vision pti envisions a future in which posttensioning is the first choice for reinforcing all structures. Flexural cracks due to eccentric posttensioning forces will remain open throughout the life of the wall, and may create problems related to water penetration, freezethaw or corrosion. Flexural cracking due to sustained post tensioning forces is believed to be more severe than cracking due to transient loading. On the basis of limited data, the following expression has been suggested to estimate the maximum crack width in direct tension aci 224r. It has the following benefits as compared to unbonded post tensioning. Posttensioned concrete corrosion the principal cause of corrosion of posttension tendons is the presence of moisture and air voids around the strands.
Before a post tension slab is poured, highstrength steel strands or cables, called tendons, are laid in a tight grid. I have been retained as a third party to evaluate a post tensioned tennis court. Post tension concrete dubaiuae, cairoegypt and riyadh. Identifying problems with post tension concrete post tensioning is a technique for reinforcing concrete with steel cables, typically referred to as tendons. Preventing cracks on posttensioned concrete slabs pro. In order to ensure that the posttension slab used will have the best chance of avoiding. Issues in posttensioned construction concrete construction. When the foundation concrete has sufficiently hardenedcured, the plasticsheathing is stretchedelongated. It is substantially prestressed during production, in a manner that strengthens it against tensile forces which will exist when in service 35 this compression is produced by the tensioning of highstrength tendons located within or adjacent to the concrete and is done to improve the performance of the concrete in service. Inspection of posttensioned parking structures shows that expansion joints in parking floors are subject to a number of problems including inadequate sealing, spalled slab bearings and insufficient concrete cover over tendon anchors. The causes of each type of cracking depend on many different factors, and may affect appearance only, or they may indicate significant structural distress or a lack of durability. This book is destined to become the definitive work on the design of post tensioned concrete buildings for many decades to come.
Many people dont understand how they work and the benefits. Inspection of post tensioned parking structures shows that expansion joints in parking floors are subject to a number of problems including inadequate sealing, spalled slab bearings and insufficient concrete cover over tendon anchors. Flexural and tensile crack widths can be expected to increase with time for. Five advantages of posttensioning over standard reinforcing steel rebars. Effective inspection and monitoring of posttensioned. Bridge division office of engineering federal highway administration washington, d. Understanding the causes of some of these problems should help contractors build better posttensioned structures. It can withstand strong mother nature storms, cushioned systems can be applied on the slab and works great both indoor and out. Grisolia, with almost a decade of experience in the home building industry, has assisted housing giants affected by quality issues like cracking in posttensioned slabs in southwest markets. For example, a concrete wall can support tons of weight from above, but will crack easily if pushed sideways forcing it to bend.
Posttensioned concrete construction is a little different than standard reinforced concrete construction. Also, because aci 302 says a reasonable level of cracking is from 0% to 3%, it implies that no cracking, 0%, is a possible, reasonable level. Causes and prevention of problems in largescale prestressed. The cause of cracking in posttensioned concrete box. We recommend using pt for temperature and shrinkage reinforcement.
This means the foundation is reinforced by cables laid in a grid arrangement and tensioned after the concrete cures sufficiently with the intent to create compression in the foundation concrete to resist cracking. Similarly, a slab will crack if too much weight is placed in one spot, or if the soil settles unevenly, bending the slab. Neglecting to design general anchorage zones or delegating this responsibility. All concrete will shrink during the curing process which lasts up to a year after the time concrete is placed in the forms. The advantages of posttensioned structures a technique that allows long beams lengths to be achieved reduces deflections and allows highspan depth ratios improves durability by the reduction or elimination of cracking more efficient utilization of steel and concrete material. On the other hand post tension slabs allow for the soil compaction due to decay and are strong enough to avoid the associated cracking. A posttension slab is a slab of concrete that has been prestressed using a specific method to increase the strength of the concrete. Other types of concrete cracking such as due to impact or loading are discussed in other articles at this website. The advantages of post tensioned structures a technique that allows long beams lengths to be achieved reduces deflections and allows highspan depth ratios improves durability by the reduction or elimination of cracking more efficient utilization of steel and concrete material. With concrete, weather is an important factor, as wet or dry conditions can significantly change the timing of when you stress the tendons. Consulting construction engineer san francisco, california also, professor of civil engineering, university of california at berkeley as each new construction technology is applied extensively, we gain the confidence and capability to exploit its potential to ever more. Once it cures, we pull the ends of the tendons, which try to straighten out. It reduces or eliminates shrinkage crackingtherefore no joints, or fewer joints, are needed.
Cracks may represent the total extent of the damage, or they may point to problems of greater magnitude. A post tension slab is a concrete slab or foundation that contains high tension cables running through the concrete to increase strength and reduce cracking typically in areas with poor soil conditions. It reduces or eliminates shrinkage crackingtherefore no joints, or fewer joints, are. This book is destined to become the definitive work on the design of posttensioned concrete buildings for. My posttension elevator speech is pretty well rehearsed at this point. As a result, even though post tensioning is meant to help prevent a slab from cracking, the slab can still crack if the tensioning process is done incorrectly. Conventional uses more steel less concrete, post tension uses more concrete less steel at least on all of my designed slabs in east texas where expansive soil is just part of the game. Post tensioning is a method of reinforcing strengthening concrete or other materials with highstrength steel strands or bars, typically referred to as tendons. Posttensioning is a method of reinforcing strengthening concrete or other materials with highstrength steel strands or bars, typically referred to as tendons. Top 10 biggest mistakes made in posttensioned concrete. This problem is exacerbated by the buildings proximity to the ocean and the.